Thank you for taking interest in the Standard Industries part number 1892, a Transformer Power product that we stock that is presented alongside the NSN 5950-01-217-6349 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number 1892 specifically traces back to Standard Industries through the CAGE Code 23951, a distinct identifier for one of their physical locations. Moreover, with the NSN 5950-01-217-6349, this listing falls within Federal Supply Code (FSC) 5950 Coils and Transformers, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number 1892 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-217-6349 Item PartTypeName: TRANSFORMER,POWER | 5950 | 012176349 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
14060 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 18.5 KILOHERTZ MINIMUM AND 30.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAV | OVERALL DIAMETER | 1.900 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 19.0 MILLIAMPERES AC MINIMUM AND 21.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 19.0 MILLIAMPERES DC MINIMUM AND 21.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.66 AMPERES DC MINIMUM AND 2.94 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.99 AMPERES DC MINIMUM AND 6.62 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.41 AC VOLTS MINIMUM AND 17.07 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 21.32 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS MINIMUM AND 37.56 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.49 AC VOLTS MINIMUM AND 6.82 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 60.70 AC VOLTS MINIMUM AND 64.40 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 PIN |