Thank you for taking interest in the Spd Electrical Systems Inc part number ETN6304, a Tripper Circuit Breaker product that we stock that is presented alongside the NSN 5925-00-227-0384 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number ETN6304 specifically traces back to Spd Electrical Systems Inc through the CAGE Code 30086, a distinct identifier for one of their physical locations. Moreover, with the NSN 5925-00-227-0384, this listing falls within Federal Supply Code (FSC) 5925 Circuit Breakers, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number ETN6304 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-227-0384 Item PartTypeName: TRIPPER,CIRCUIT BREAKER | 5925 | 002270384 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ETN6304 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.625 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 150.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | 1170.0/1365.0 AC ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3600.000 NOMINAL AT 150 PCT ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote