Thank you for taking interest in the Sensata Technologies Inc part number AP112-1RC65-203, a Circuitbreaker product that we stock that is presented alongside the NSN 5925-01-475-0485 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number AP112-1RC65-203 specifically traces back to Sensata Technologies Inc through the CAGE Code 81541, a distinct identifier for one of their physical locations. Moreover, with the NSN 5925-01-475-0485, this listing falls within Federal Supply Code (FSC) 5925 Circuit Breakers, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number AP112-1RC65-203 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-475-0485 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014750485 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP112-1RC-65-203 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS AND 7.5 AMPERES AC ALL LOCATIONS AND 20.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES NOMINAL |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC ALL LOCATIONS AND 800.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS AND 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
ADAT | Body Width | 0.625 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING AND 2 THREADED HOLE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
THSD | Thread Series Designator | UNEF |
CPRQ | Reset Method | AUTOMATIC |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADTV | Case Material | METAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP W/AUXILIARY LOAD TERMINAL ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES NOMINAL |
AAQL | Body Style | |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.500 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 8.000 NOMINAL AT 125 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 6 WIRE HOOK |