Thank you for taking interest in the Sensata Technologies Inc part number UPGN-66-1-62-252, a Circuitbreaker product that we stock that is presented alongside the NSN 5925-01-452-9853 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number UPGN-66-1-62-252 specifically traces back to Sensata Technologies Inc through the CAGE Code 81541, a distinct identifier for one of their physical locations. Moreover, with the NSN 5925-01-452-9853, this listing falls within Federal Supply Code (FSC) 5925 Circuit Breakers, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number UPGN-66-1-62-252 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-452-9853 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014529853 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
211726 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 2.5 AMPERES DC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERVOLTAGE ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3500.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.625 INCHES NOMINAL |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE TWO |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
ADAU | Body Height | 2.232 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.