Thank you for taking interest in the Navair And Navsea Managed part number 2868625-1, a Resistor Network Fixed Wirewound product that we stock that is presented alongside the NSN 5905-00-405-2433 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number 2868625-1 specifically traces back to Navair And Navsea Managed through the CAGE Code 10001, a distinct identifier for one of their physical locations. Moreover, with the NSN 5905-00-405-2433, this listing falls within Federal Supply Code (FSC) 5905 Resistors, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number 2868625-1 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-405-2433 Item PartTypeName: RESISTOR NETWORK,FIXED,WIRE WOUN | 5905 | 004052433 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
183146 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -260.0/260.0 |
AAPP | ELECTRICAL RESISTANCE | 101.716 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 119.985 KILOHMS 10TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 13.506 KILOHMS LOWEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 139.985 KILOHMS 11TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 14.063 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 159.985 KILOHMS 12TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 179.985 KILOHMS 13TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 180.000 KILOHMS 14TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 225.704 KILOHMS HIGHEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 26.013 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 28.156 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 39.985 KILOHMS 4TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 59.985 KILOHMS 5TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 79.985 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 80.000 KILOHMS 7TH INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 99.985 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000/5.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0/145.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 20 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.135 INCHES MINIMUM |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.650 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 TOTAL NETWORK |
CBME | CUBIC MEASURE | 1.950 CUBIC INCHES |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 10TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 11TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 12TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 13TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 14TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 2ND INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 3RD INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 4TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 5TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 6TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 8TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 9TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 7TH INTERMEDIATE RESISTANCE VALUE |
FEAT | SPECIAL FEATURES | NON-INDUCTIVE |
STYL | STYLE DESIGNATOR | DUAL INLINE |
TEST | TEST DATA DOCUMENT | 10001-2868625 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |