Thank you for taking interest in the Military Specifications part number MIL-C-3432, a Cable Power Electri product that we stock that is presented alongside the NSN 6145-01-334-1393 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number MIL-C-3432 specifically traces back to Military Specifications through the CAGE Code 81349, a distinct identifier for one of their physical locations. Moreover, with the NSN 6145-01-334-1393, this listing falls within Federal Supply Code (FSC) 6145 Wire and Cable Electrical, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number MIL-C-3432 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6145-01-334-1393 Item PartTypeName: CABLE,POWER,ELECTRICAL | 6145 | 013341393 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
MIL-C-3432 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
ABJH | TEMP RATING | -40.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
AMQN | CONDUCTOR QUANTITY | 4 |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER 2ND POSITION SHIELD BRAID,METALLIC CABLE |
MATT | MATERIAL | RUBBER BUTADIENE-STYRENE CLASS SBR OR RUBBER ETHYLENE-PROPYLENE CLASS EPM OR RUBBER ETHYLENE-PROPYLENE-DIENE CLASS EPDM 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATT | MATERIAL | RUBBER BUTADIENE-STYRENE CLASS SBR 3RD POSITION JACKET CABLE |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-I-3930 TYPE JS OR JN SBR MIL SPEC SINGLE MATERIAL RESPONSE 2ND POSITION JACKET CABLE |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.520 INCHES NOMINAL |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 41 ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 4 SINGLES |
HUES | COLOR | GREEN 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-W-343 SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN 2ND POSITION SHIELD BRAID,METALLIC CABLE |
CXDC | ROUND CONDUCTOR SIZE | 14 AWG ALL CONDUCTORS |
HUES | COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
HUES | COLOR | RED 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-I-3930 TYPE IS OR IH SBR,EPM,OR EPDM MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |