Thank you for taking interest in the General Motors Corp part number 1118089, a Relay Electromagnetic product that we stock that is presented alongside the NSN 5945-00-295-6987 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number 1118089 specifically traces back to General Motors Corp through the CAGE Code 7X677, a distinct identifier for one of their physical locations. Moreover, with the NSN 5945-00-295-6987, this listing falls within Federal Supply Code (FSC) 5945 Relays and Solenoids, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number 1118089 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-295-6987 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 002956987 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
19851 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 7.453 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.688 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.438 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.281 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND WATERTIGHT |
AKDX | WINDING QUANTITY | 2 |
APCN | COIL QUANTITY | 2 |
APNA | WINDING DC RESISTANCE RATING | 0.2 OHMS NOMINAL FIRST WINDING |
APNA | WINDING DC RESISTANCE RATING | 0.83 OHMS NOMINAL SECOND WINDING |
APNP | DUTY TYPE | INTERMITTENT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 11.0 AMPERES DC SECOND WINDING AND 13.0 AMPERES DC SECOND WINDING |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 49.0 AMPERES DC FIRST WINDING AND 55.0 AMPERES DC FIRST WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 10.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 12.0 DC |
FEAT | SPECIAL FEATURES | CORROSION RESISTANT |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |