Thank you for taking interest in the Freed Transformer Company part number 41389, a Reactor product that we stock that is presented alongside the NSN 5950-00-004-2071 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number 41389 specifically traces back to Freed Transformer Company through the CAGE Code 73386, a distinct identifier for one of their physical locations. Moreover, with the NSN 5950-00-004-2071, this listing falls within Federal Supply Code (FSC) 5950 Coils and Transformers, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number 41389 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-004-2071 Item PartTypeName: REACTOR | 5950 | 000042071 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
41389 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND VIBRATION RESISTANT AND FLAME RESISTANT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.140 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.090 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.110 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.146 INCHES MINIMUM SINGLE GROUP AND 0.166 INCHES MAXIMUM SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
ACYV | INDUCTANCE RATING | 9.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.450 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.780 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.500 SINGLE COMPONENT SINGLE WINDING |
TEST | TEST DATA DOCUMENT | 82577-986056 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS,INDIVIDUAL MANUFACTUREER STANDARDS,ETC.). |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG |