Thank you for taking interest in the Eaton Corporation part number AM3-C3-6-3, a Circuit Breaker product that we stock that is presented alongside the NSN 5925-01-069-3437 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number AM3-C3-6-3 specifically traces back to Eaton Corporation through the CAGE Code 74193, a distinct identifier for one of their physical locations. Moreover, with the NSN 5925-01-069-3437, this listing falls within Federal Supply Code (FSC) 5925 Circuit Breakers, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number AM3-C3-6-3 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-069-3437 Item Description: Circuit Breaker | 5925 | 010693437 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Am3-C3-6-3 | 2 | 1 | C | N |
MRC | Criteria | Characteristic |
---|---|---|
ZZZK | Specification/Standard Data | 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 6.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
TEST | Test Data Document | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
ADAT | Body Width | 1.469 INCHES MINIMUM AND 1.530 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
THSD | Thread Series Designator | UNC |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT EACH POLE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.522 INCHES MINIMUM AND 2.553 INCHES MAXIMUM |
ADAQ | Body Length | 2.479 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
MRC | Decoded Requirement | Clear Text Reply |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.800 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote