Thank you for taking interest in the Dickson part number TH300, a Hygrothermometer Di product that we stock that is presented alongside the NSN 6685-01-462-7959 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number TH300 specifically traces back to Dickson through the CAGE Code 0P3J6, a distinct identifier for one of their physical locations. Moreover, with the NSN 6685-01-462-7959, this listing falls within Federal Supply Code (FSC) 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number TH300 here on Aero OEM Parts at your earliest convenience.
MRC | Criteria | Characteristic |
---|---|---|
STYL | Style Designator | HAND HELD |
ASXH | Voltage Rating In Volts | 9.0 DC NOMINAL |
AGAV | End Item Identification | PACER SPECIAL |
BFQP | Display Digit Quantity | 4 |
BFHZ | Measurement Type | THERMOELECTRICAL CIRCUIT |
BFQN | Display Type | LIQUID CRYSTAL |
ABHP | Overall Length | 7.000 INCHES NOMINAL |
FEAT | Special Features | TEMPERATURE RANGE -22 TO +185 DEG F, -30 TO +85 DEG C; TEMPERATURE ACCURACY +/- 1.8 DEG F (+/-1 DEG C); HUMIDITY RANGE 0 TO 95% RH (NON-CONDENSING);HUMIDITY ACCURACY +/-2 PERCENT FROM 0 TO 60 PERCENT RH; +/-3 PERCENT FROM 61 TO 95PERCENT RH; AVERAGE RESPONSE TIME 3 SECONDS TO MOVE 60 PERCENT OF SCALE; CALCULATED DEW POINT RANGE -20 TO +120 DEG F; -30 TO +50 DEG C; CALCULATED DEW POINT ACCURACY +/-2 DEG C (+/-3 DEG F) FROM 30 TO 95 PERCENT RH; ONE 9 VOLT BATTERY; NUMERAL HEIGHTH .9 INCHES; STORES 16 READINGS |
BHMC | Case Type | CARRYING CASE W/HANDLE |
MRC | Decoded Requirement | Clear Text Reply |
BHMW | Measurement Range | -30.0/+85.0 DEG CELSIUS AND -22.0/+185.0 DEG FAHRENHEIT AND +0.0/+95.0 PERCENT RELATIVE HUMIDITY |
BGJN | Switch Type And Quantity | 8 PUSH BUTTON |
ABMK | Overall Width | 2.750 INCHES NOMINAL |
SPCL | Special Test Features | COMES WITH ONE POINT NIST TRACEABLE CERTIFICATION OF CALIBRATION |
ABFY | Overall Depth | 1.350 INCHES NOMINAL |
CXCY | Part Name Assigned By Controlling Agency | THERMOHYROMOTER; TEMPERATURE/HUMIDITY/DEW POINT INDICATOR |
MATT | Material | PLASTIC OVERALL |