Thank you for taking interest in the Chromalox Corp part number 049197-001, a Switch Thermostatic product that we stock that is presented alongside the NSN 5930-00-602-1599 for ease of identification. If you would like to learn more about this component and secure purchasing options for your consideration, please fill out and submit the Request for Quote (RFQ) form that is offered below. All we ask is that you supply us with enough information to best accommodate any particular requirements or restrictions that you may have, and we will respond with a curated quote within 15 minutes of our receipt and review.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to ensure that customers only receive precise items of need, opting to arrange our collection by diverse, commonly recognized forms of data. For instance, part number 049197-001 specifically traces back to Chromalox Corp through the CAGE Code 65586, a distinct identifier for one of their physical locations. Moreover, with the NSN 5930-00-602-1599, this listing falls within Federal Supply Code (FSC) 5930 Switches, enabling one to figure out its basic application. Keeping this in mind, do not hesitate to obtain a competitive quote for part number 049197-001 here on Aero OEM Parts at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-602-1599 Item Description: SWITCH,THERMOSTATIC | 5930 | 006021599 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
049197-001 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQGB | Contact Action Stimulus | DECREASE |
ABHP | Overall Length | 2.1875 INCHES NOMINAL |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE |
AXGY | Mounting Method | THREADED HOLE AND |
AEVT | Capillary Tube Length | 15.0 INCHES NOMINAL |
AAJD | Thread Class | 2B SINGLE PRESSURE CONNECTION |
CTYM | Contact Adjustment Range | 55.00 TO 105.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | Contact Adjustment Type | EXTERNAL ACTUATION POINT DIAL |
CTYC | Contact Adjustability | ACTUATION POINT ADJUSTABLE |
ABMK | Overall Width | 1.250 INCHES NOMINAL |
CTYX | Contact Stimulus Rating | 3.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | Contact Voltage Rating In Volts | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
STYL | Style Designator | RECTANGULAR |
CRLD | Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
AXGY | Mounting Method | UNTHREADED HOLE |
CTYC | Contact Adjustability | DEACTUATION POINT NOT ADJUSTABLE AND |
CTZB | Contact Voltage Rating In Volts | 277.0 AC AT SEA LEVEL FIRST VOLTAGE |
AEJN | Distance Between Mounting Facility Centers | 1.750 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.138 INCHES SINGLE PRESSURE CONNECTION |
ADAQ | Body Length | 1.4375 INCHES NOMINAL |
AEVU | Bulb Length | 5.500 INCHES NOMINAL |
ABKW | Overall Height | 2.6875 INCHES NOMINAL |
THSD | Thread Series Designator | UNC SINGLE PRESSURE CONNECTION |
AKBY | Temp Sensing Element Type | CAPILLARY TUBE-BULB |
CTHF | Contact Load Current Rating | 22.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | Contact Load Current Rating | 25.0 AMPERES RESISTIVE LOAD AND |
CTHF | Contact Load Current Rating | 10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CMLP | Thread Quantity Per Inch | 32 SINGLE PRESSURE CONNECTION |
AEJN | Distance Between Mounting Facility Centers | 1.3125 INCHES MINIMUM AND |
CSCF | Terminal Type | WIRE LEAD |
MEDA | Media For Which Designed | GAS |
AEVV | Bulb Diameter | 0.375 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.4375 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |