MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM FIRST FLANGE AND 0.903 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM SECOND FLANGE AND 0.903 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM FIRST FLANGE AND 0.403 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM SECOND FLANGE AND 0.403 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.000 INCHES MINIMUM FIRST FLANGE AND 1.006 INCHES MAXIMUM FIRST FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.000 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY AND 0.172 INCHES MAXIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.06 |
CQGM | MAXIMUM OPERATING PRESSURE | 5.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.997 INCHES MINIMUM AND 1.003 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 2.870 INCHES MINIMUM AND 2.930 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CHOKE TYPE ALL FLANGES |
CWBG | WAVEGUIDE OFFSET DISTANCE | 0.610 INCHES MINIMUM AND 0.670 INCHES MAXIMUM |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | RUBBER SYNTHETIC SINGLE TUBING JACKET |
MATT | MATERIAL | STEEL CORROSION RESISTING SINGLE TUBING SEGMENT |
SFTT | SURFACE TREATMENT | NICKEL SINGLE TUBING SEGMENT INSIDE SURFACES |
STYL | STYLE DESIGNATOR | BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SINGLE CONNECTION FACILITY |